Product Description
|
Range of application:
- Suitable for speed governing scale, constant speed scale, static state scale - Belt measurement of large material level - Measuring accuracy of instrument: 0.05 percent - Convenient to connect DCS system - Networking TW3000 |
Performance Feature
|
1. It applies professional and technical grade control MPU, which is stable and reliable.
2. Apply E2ROM to protect data 3. It applies low-temperature float and LNA for lower instrument’s drifting. 4. Multichannel analog input, multichannel analog output Analog input: 16 digit, analog output: 12 digits 5. Automatic zero calibration 6. Environmental temperature: 0~ 7. Measurement accuracy of instrument: better than 0.05 percent 8. LCD display, 20 kays, single luminescent tube display 9. Suitable for speed governing scale, constant speed scale, static state scale
A: optoelectronic isolation of on-off input and output B: pulse-speed input, optoelectronic isolation C: external switching turn on/off D: external flow input (full isolation): 0~10mA or 0~20mA or 4~20mA E: Current Flow output (full isolation): 0~10mA or 0~20mA or 4~20mA F: Sensor Power Supply: 6V, electric current: 150mA G: on-off output: alert indication, operating indication, power on ready H: Instrument has 2-level magnify function: one for hardware, two for programmable gain. |